The Causes and Preventions and Controls of the Abuse of Long-lasting Mushrooms

Bags of mushroom bulbs grow thick white villous hyphae on their surfaces, and some grow up and fall down, then fall down and grow. The fungal skin gradually thickens; some do not even fall flat, and the color cannot be changed. This is the phenomenon of "hyperplasia".

1. The reason for the occurrence.

1 The window of the mushroom cultivation room is too small, and the interior light is too dark.

2 The moisture content of the culture material is high, and the indoor air humidity in the cultivation room is high.

3 The lack of ventilation, especially when the mycelium began to thicken and need to increase ventilation, but lack of ventilation.

4 The tilt film is too light or the film is too short.

5 Ingredients to add too much nutrients such as corn flour.

2. Control methods

1 Create environmental conditions conducive to fruit body growth during fruiting.

2 When the mushroom mycelium is thick and white, up to 2 cm in diameter and still not lodging, and there is uneven hyphae, it is necessary to open the film and vent until the growing bag and around the sticky hands are covered with a film. The next day, it is not necessary to lift the membrane, allowing the moisture on the surface to force the mycelium to fall flat and turn color. If it is still not lying down, open the film again, open the door and window, and after the material surface is dry, use a soft row brush to lightly disturb the surface mycelium and force it to turn over.

3 can also be dried in the material surface, sprayed with 5% lime clarified liquid once, sprayed and then aired, and then covered with a film, generally will fall down and turn color.

Double Head Ultrasound Series

pecification
-Probe Type: Consist by two of Convex, Microconvex, Linear, Small Linear, Transvaginal
-Scanning mode: Electronic array
-Display mode: B, B/M, color doppler version with B+Color, B+PDI, B+PW
-Probe element: 128/192
-Channel of RF circuit board: 32/64
-Probe frequency and scan depth, head radius/width, scan angle(convex):
Convex head 3.5MHz/5MHz, 90/160/220/305mm, 60mm, 60°
Convex head with phased array(cardiac) scan mode: 3.5MHz/5MHz, 90/160/220/305mm, 40mm, 90°
Linear head 7.5MHz/10MHz, 20/40/60/100mm, 40mm
Small Linear head 10MHz/14MHz, 20/30/40/55mm, 25mm
Microconvex head 3.5MHz/5MHz, 90/130/160/200mm, 20mm, 88°
Transvaginal head 6.5MHz/8MHz, 40/60/80/100mm, 13mm, 149°
-Image Adjust: BGain, TGC, DYN, Focus, Depth, Harmonic, Denoise, Color Gain, Steer, PRF
-Cineplay: auto and manual, frames can set as 100/200/500/1000
-Puncture assist function: the function of in-plane puncture guide line, out-of-plane puncture guide line, automatic blood vessel measurement.
-Measure: Length, Area, Angle, heart rate, Obstetrics
-Image save: jpg, avi and DICOM format
-Image frame rate: 18 frames/second
-Battery working time: 2.5 hours(according to whether keep scan)
-Battery charge: by USB charge or wireless charge, take 2 hours
-Dimension: L156×W60×H20mm(if with transvaginal head length is 270mm)
-Weight: 250g
-Wifi type: 802.11g/20MHz/5G/450Mbps
-Working system: Apple iOS and Android, Windows

Double Head Ultrasound,Wireless Machine Double Head Linear,Double Head Probe Type Wireless Ultrasound,Double Head Wireless Ultrasound