Hb-Yp90ab Medical Equipment Neonatal Baby Infant Incubator

Model NO.: HB-YP90AB
Factory Location: 1.5 Hours From Shanghai
Power Requirement: AC220V-230V/50Hz
Environment Temperature: 20 °c -30°c
Gross Weight (Main Body): 63kg
Trademark: WANROOEMED
Transport Package: Wooden Package
Specification: 1085mm x 640mm x 910mm
Origin: China
HS Code: 9018909000
HB-YP90AB Medical Equipment Neonatal Baby Infant Incubator
Hb-Yp90ab Medical Equipment Neonatal Baby Infant Incubator

Brief Introduction:
Air mode control, set temperature and air temperature are displayed separately;
Natural air flow humidity
Inclination of bassinet is adjustable
Failure alarm indication
RS-232 connector
Oxygen input interface
HB-YP90B is configured with fixed Neonate Bilirubin Phototherapy Equipment model: HBXHZ-90 (with blue fluorescence lamps);
DC motor

 
Standard  configuartion:
HB-YP90:the hood ,the base ,the controller ,I.V pole ,shelf.
HB-YP90B:Based on HB-YP90,with Neonate bilirubin phototherapy equipment (fixed model)
 

Optional parts:
> 37°C temperature override mode function, vertical height adjustment stand(VHA stand), Weighing system, Neonate bilirubin phototherapy equipment model: XHZ-90L (fixed model), Baby mode and SPO2.
 
Specification:

Power requirement: AC220V-230V/50Hz or AC110-120V/50-60Hz, 850VA
Mode of control: Air mode control
Air temperature control range: 25°C -37°C (override mode: 37-39°C is optional)
The temperature difference between incubator temperature and average incubator temperature(under steady temperature condition)≤0.5°C
Temperature uniformity: 0.8°C (mattress is on the horizontal position)
Inclination of the bassinet: ±12°
Noise inside hood: 45dB(A)
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, fan motor alarm, power failure alarm, system alarm and so on.
The average value of total irradiance for bilirubin Ebi max of phototherapy equipment:
≥ 640pW/cm2 ( XHZ-90 ) •
≥1300pW//cm2 ( HBXHZ-90L )
Built-in timer range: 0-9999 hrs 59min
Accuracy of weight display: ±1% (equipped weighing system)

 
Power requirement: AC220V-230V/50Hz or AC110-120V/50-60Hz, 850VA
Air temperature control range: 25°C -37°C
Noise inside hood: 45dB(A)
Accuracy of weight display: ±1%
Ambient air movement rate: <0.3m/s
Product Packaging: 1085mm x 640mm x 1120mm

 
Environmental temperature:
Operating range: 20 °C -30°C (Set temperature should be higher 3°C than the environment temperature)
Ambient air movement rate: <0.3m/s

 
Product Packaging:
Package: each unit is packed into one carton
Dimension: 1085mm x 640mm x 1120mm
Gross Weight: 80Kg (for HB-YP90)
              90Kg (for HB-YP90B)


Details:
Hb-Yp90ab Medical Equipment Neonatal Baby Infant Incubator
Hb-Yp90ab Medical Equipment Neonatal Baby Infant Incubator
Hb-Yp90ab Medical Equipment Neonatal Baby Infant Incubator

About Wanrooemed:
Hb-Yp90ab Medical Equipment Neonatal Baby Infant IncubatorHb-Yp90ab Medical Equipment Neonatal Baby Infant Incubator

 

Non Woven Face Masks

Face Mask,Surgical Face Mask,Non Woven Face Mask

Disposable Syringes Co., Ltd. , http://www.nsmedicalcannula.com